Tier 4 data centers in Hong Kong and how to check their certification
Ask whether Hong Kong has a Tier IV data center, and you will hear two answers. DCI records 10 operating facilities at Tier 4, together running 267.6 MW, about a sixth of the city’s IT load. Separately, NTT Hong Kong Financial Data Center holds Uptime Institute Tier IV Certification of Design Documents, awarded on 3 June 2014. DCI records its tier as Tier 2; the design award and DCI classification are separate fields.
Published November 25, 2026
- 10 sites, 267.6 MW
- Recorded Tier 4, operating
- 4 projects, 120.9 MW
- Recorded Tier 4, pipeline
- 1
- Uptime Tier IV awards on record
- 1 (Equinix HK6)
- Tier 4 sites with confirmed liquid cooling
Mordor Intelligence, Data Center Intelligence research team. Facility checks November 2026.
Key takeaways
- Tier 4 by record, not by certificate.Hong Kong’s 10 Tier 4 facilities are Tier 4 in their design records; NTT Hong Kong Financial Data Center separately holds a Tier IV design award in DCI’s records.
- One design award is recorded.NTT Hong Kong Financial Data Center holds Tier IV Certification of Design Documents from Uptime Institute.
- AI-ready Tier 4 space is scarce today.Only Equinix HK6 has confirmed liquid cooling.
- High density arrives from 2027.All four Tier 4 projects in the pipeline are designed for 60–100 kW per rack.
Tier IV, Rated 4 and “Tier 4”: what the labels mean
Does Hong Kong have Tier 4 data centers?
Which Hong Kong facilities does DCI list as Tier 4?
| Facility | Operator | Locality | IT load (MW) | Opened | Rack density (kW) | Power redundancy |
|---|---|---|---|---|---|---|
| The Mega IDC | SUNeVision | Tseung Kwan O | 50.0 | 2024 | 12 | N+1 |
| AirTrunk HKG2 | AirTrunk | East New Territories | 47.4 | 2024 | 20 | N+1 |
| Tsuen Wan West Campus (1 building) | Goodman Group | Tsuen Wan | 38.9 | 2022 | 10 | N+1 |
| Cloud Computing Complex | hkcolo | Tseung Kwan O | 32.8 | 2011 | 3 | N+1 |
| HK1 Phase 2 | DayOne (GDS) | Kwai Chung | 32.5 | Q4 2024 | 13 | N+1 |
| UniCom Global Intelligent – Cloud Data Center | China Unicom (Hong Kong) | Tseung Kwan O | 27.0 | 2016 | 6 | N+1 |
| The Mega Gateway | SUNeVision | Tsuen Wan | 14.1 | 2023 | 10 | N+1 |
| HK6 | Equinix | Tsuen Wan | 12.5 | Q2 2026 | 6 | N+1 |
| HKG8 | BDx | Kwai Chung | 11.3 | 2023 | 8 avg, 15 max | N+1 |
| Tai Po DC1 | AsiaSat | Tai Po | 1.1 | 2011 | 5.6 | 2N |
HKG8 rack density is taken from BDx’s data sheet. Goodman’s Tsuen Wan West campus has three buildings, each rated at 38.9 MW; only one is recorded at Tier 4, so a buyer should match any tier claim to the exact building and phase.
Not on the list: Vantage HKG3
How much Hong Kong capacity does DCI classify as Tier 4?
| Tier | Operating projects | Operating IT load (MW) | Under construction (MW) | Announced (MW) | Share of operating load |
|---|---|---|---|---|---|
| Tier 4 | 10 | 267.6 | 105.0 | 15.9 | 16.3% |
| Tier 3 | 30 | 883.1 | 190.1 | 65.0 | 53.8% |
| Tier 2 | 45 | 344.2 | – | – | 21.0% |
| Tier 1 | 10 | 147.8 | – | – | 9.0% |
New capacity is built only for Tier 3 and Tier 4. The pipeline totals 376.0 MW across 11 projects, with Tier 4 accounting for about a third, 120.9 MW across 4 projects.
Which Tier 4 data centers are best suited to AI workloads?
Where liquid cooling runs in Hong Kong today
| Facility | Operator | Locality | Recorded tier | Liquid cooling |
|---|---|---|---|---|
| HK6 | Equinix | Tsuen Wan | Tier 4 | Direct-to-chip, opening in June 2026 |
| Hong Kong data center Phase 1 | Global Switch | Tseung Kwan O | Tier 3 | Direct-to-chip and rear-door heat exchangers since September 2024; up to 100 kW per rack in demand |
| Hong Kong IBX HK1 | Equinix | Tsuen Wan | Tier 3 | Liquid cooling added with Schneider Electric, Dell Technologies and CLP in 2025 |
| Financial Datacenter (FDC) | NTT DATA | Tseung Kwan O | Tier 2 | Direct liquid cooling for HPC above 50 kW per rack, since April 2024 |
| Tai Po Data Center | NTT DATA | Tai Po | Tier 1 | Direct liquid cooling for HPC above 50 kW per rack, since April 2024 |
Planned Tier 4 data center projects in Hong Kong
| Project | Operator | Locality | Status | IT load (MW) | Rack density (kW) | Expected |
|---|---|---|---|---|---|---|
| Mega IDC Phase 2 | SUNeVision | Tseung Kwan O | Under construction | 65.0 | 80 | 2027–2028 |
| HKG09 | Goodman Group | Kwai Chung | Under construction | 28.0 | 60 | 2029 |
| Tuen Mun Data Center | TPG Angelo Gordon | Tuen Mun | Announced | 15.9 | 100 | 2028 |
| Tower 3 (Phases 1 and 2) | iTech Towers | Fanling | Under construction | 12.0 | 70 | 2027 |
DCI dates Mega IDC Phase 2 to 2027; SUNeVision told shareholders in June 2026 that it is accelerating Phases 2 and 3 toward operation in 2028. Grand Ming Group, which owns iTech Towers, describes Tower 3 as a Tier IV-ready design with 2N power.
The largest project in the wider pipeline is China Telecom Global’s 84.0 MW TKO2 Phase 2 in Tseung Kwan O, a Tier 3 project due in 2026 at 70 kW per rack.
Note: data as of November 2026.
How to check a Tier 4 claim before you sign
- 01Ask for the award.Obtain the Uptime Tier award or design certificate from the operator, and verify that it identifies the exact building and phase you are buying.
- 02Review the single-line design.Confirm that power and cooling paths are genuinely independent, not N+1, before paying a Tier IV premium.
- 03Confirm cooling and per-rack power.For AI workloads, ask for the cooling method and the power available on liquid-cooled racks, not the hall average.
- 04Confirm space and dates.Check that the space and power you need are available on your required dates.
Questions about Tier 4 data centers in Hong Kong
01
Are there Tier 4 data centers in Hong Kong?
DCI records 10 operating Hong Kong data centers at Tier 4, with 267.6 MW of IT load, led by SUNeVision’s The Mega IDC and AirTrunk HKG2. NTT Hong Kong Financial Data Center separately holds a Tier IV design award in DCI records.
02
Does any Hong Kong data center hold Uptime Institute Tier IV certification?
DCI records Tier IV Certification of Design Documents for NTT Hong Kong Financial Data Center. This is a design award. Buyers should check the award for the exact building and ask separately for certification of the constructed facility.
03
Which Hong Kong data centers use liquid cooling?
Five facilities have liquid cooling confirmed by their operators: Equinix HK6 and HK1, Global Switch’s Tseung Kwan O data center, and NTT DATA’s Financial Datacenter and Tai Po Data Center. Only HK6 is recorded at Tier 4.
04
Is Vantage HKG3 a Tier 4 data center?
No. DCI records Vantage’s Kwai Chung (HKG3) facility at Tier 3, with 14.0 MW of IT load, N+1 and N+2 power redundancy, and N+1 cooling.
05
How many data centers are in Hong Kong?
DCI tracks 106 Hong Kong data center projects run by 52 operators: 95 operating, 9 under construction, and 2 announced.
06
Does Data Center Intelligence offer a free trial?
Yes. The DCI team starts with a 30-minute walkthrough tailored to your market, then opens a trial for your team.
Explore the Hong Kong projects in DCI.
DCI holds the full Hong Kong list with filters for locality, operator, status, tier, rack density, and power and cooling redundancy, along with addresses and coordinates for each project. A demonstration walks through the facilities and projects that match your market or supplier brief. For a new development, use the DCI site selection tool to compare candidate locations against your project requirements. For addresses and district coverage across all recorded tiers, see the Hong Kong data center list.
Scheduling takes two minutes. No commitment.